3G3FV MANUAL PDF

admin

procedures for installing and wiring the SYSDRIVE 3G3FV-j-CUE/EF3HV-j-CUE Please read this manual thoroughly and handle and operate the product with. The SYSDRIVE 3G3FV is OMRON’s new special-purpose inverter. It provides the harmony between performance, versatility, and simplicity. Using a unique. Manuals and User Guides for Omron SYSDRIVE 3G3FV. We have 1 Omron SYSDRIVE 3G3FV manual available for free PDF download: User Manual.

Author: Fegis Malami
Country: Paraguay
Language: English (Spanish)
Genre: Software
Published (Last): 12 December 2010
Pages: 83
PDF File Size: 1.78 Mb
ePub File Size: 1.54 Mb
ISBN: 985-5-76120-461-3
Downloads: 48555
Price: Free* [*Free Regsitration Required]
Uploader: Fetaur

Chapter 5 Basic Operation Parameter F sets the conditions for detecting a PG speed deviation fault and the stopping method to be used when a fault is detected. Page – If there is noise when the inverter is s Torque Limit Function Resets the integral value with I Set the speed limit bias as a percentage of the maximum frequency.

Chapter 2 Installation Wiring Around the Main Circuit System reliability and noise resistance are affected by the wiring method used. This setting is used as a basis for motor protection Valid access levels Parameter Chapter 4 Trial Operation Initializing Parameters Initialize the parameters using the following procedure.

Page 64 Chapter 2 Installation Countermeasures Against Induction Noise As described previously, a noise filter can be used to prevent induction noise from being generated on the output side.

Vibration will occur if this setting is too short. Chapter 6 Advanced Operation When parameter d the frequency reference hold function selector is set to 1, the held frequency will be stored in memory.

Options Parameter Lists Chapter 2 Installation H Direction and Dimensions Install the Inverter on a vertical surface so that the characters on the nameplate are oriented upward. The table shows the default setting for V class, 0. Page Chapter 3 Preparing for Operation Example The following example shows how to change parameter A to select Flux Vector control vector con- trol with pulse generator.

The motor will operate during auto-tuning, so be sure that it is safe for the motor to operate before press- ing the Run Key.

  ASALA TERR RGT PDF

Omron SYSDRIVE 3G3FV Manuals

Summary Of Open-loop Vector Control Functions, Open-loop Vector Control Chapter 6 Advanced Operation Open-loop Vector Control This section summarizes the functions that can be used with open-loop vector control vector control without PG feedback and then provides detailed explanations of the functions that are specific to open-loop vector control.

Protection Parameter Lists The same kind of switching is also possible with control circuit terminals set using the multi-function input parameters 1 to 6 set value: O Chapter 6 Advanced Operation If the output torque at low speed is a problem i.

This function is specific to flux vector control. Page Chapter 6 Advanced Operation Selecting Auto-tuning Carrier Frequency The auto-tuning carrier frequency is by default set to a value higher than that used for conventional models to improve the accuracy of auto-tuning. Chapter 5 Basic Operation The parameter settings which are used most often are explained below. Chapter 8 Maintenance Operations A signal is being input to the frequency reference current terminal Actual Load Operation Decelerates to a stop Fault with C set.

Made corrections to b and b Alarm Note If the parameter is set to 3, the Inverter will operates without references from the host controller. Wiring and Connection Connect to the power supply and peripheral devices. Not doing so may result in injury. Key sequence Display Explanation Displays operation mode.

Chapter 2 Installation Note The carrier frequency setting range varies depending on the Inverter capacity. Chapter 6 Advanced Operation With this setting, the multi-function input resets faults that have occurred. Page 96 Chapter 3 Preparing for Operation S Monitoring at Startup In operation mode, the frequency reference, output frequency, output current, and output voltage can be monitored immediately if the default settings are being used.

Both settings can be changed during operation. Torque Control Chapter 6 Advanced Operation position lock for a long time, select an Inverter with a capacity one rank higher than the capacity of the motor.

  HERNIORRAFIA UMBILICAL PDF

Omron SYSDRIVE 3G3FV User Manual

Chapter 6 Advanced Operation Electronic Thermal Time Characteristics In this example, L is set to 1 minute, the motor is operating at 60 Hz, and general-purpose motor characteristics are used. Therefore, the ratio of harmonics in the output current of the Inverter is higher than that of any other electric machine. For models of 15 kW or less both V and V classdo not remove or mount the front cover without first removing the Digital Operator; Alternatively, cables can be routed through a grounded metal pipe to prevent induction noise.

VSG S April Record the current parameter settings as user defaults. Combining proportional Pintegral Iand deriva- tive D control makes control possible even for a mechanical system with dead time.

Decelerates to a Fault stop according to the C setting.

Omron SYSDRIVE 3G3FV Manuals

Be sure to follow the instructions given there. Option Error Turn off the power and insert the Card again. Caution Do not pull on the cables. The 3G3FV has a stall prevention function and an automatic torque boost function, but the motor responsiveness limit may be exceeded if acceleration is too rapid or if the load is too big.

The default setting does not normally need to be changed. Speed Deviation greater than the setting in Lighten the load. Page Chapter 6 Advanced Operation Note 2.

OMRON SYSDRIVE 3G3FV USER MANUAL Pdf Download.

Chapter 2 Installation Note 6. Chapter 6 Advanced Operation Common Functions This section summarizes the functions that can be used in common among the various modes, and provides detailed explanations of their operations.

Using the S-curve characteristic function for acceleration and deceleration can reduce shock to the machinery when stopping and starting.

Installation and Mounting Install the Inverter according to the installation conditions.